Our test and development laboratory ranks among the best in Europe. We can do 'load testing' up to 900 kW for newly designed motors or motors that have had their electrical ratings changed after being tested at nominal power. Newly designed motors are installed and tested at nominal power first. Current values, input power, losses, efficiency, power factor, moment, temperature increase under load until it reaches thermal equilibrium are measured and recorded. The noise levels of the motors are measured in a quiet room. Locked rotor tests are performed. At the end a test certificate is issued with all recorded value and curves like speed - moment - current. Our world standard laboratory is the heart of our R&D studies.